PT. Endo Indonesia

Fetal Monitor

Model : DS120B

Zondan Fetal Monitor

Fetal Monitor

10.2" inch large-screen color TFT display

Digital display and waveform oscilloscope of twins heart rate (FHR) and uterine contraction pressure(TOCO) value.

Directly viewing 1:1 scale of display and print-out waveform.

7-wafer impulse ultrasound transducer, configured with special HR self correlation reading algorithm to ensure correct and reliable fetal heart rate (FHR) measurement.

Auto power failure protection and reliable rechargeable Li-ion battery can realize continual monitoring function.



Features:

  • 10.2" inch large-screen color TFT display, digital display and waveform oscilloscope of twins heart rate (FHR) and uterine contraction pressure(TOCO) value.
  • Independent and user friendly interface with menu function setting. Unique rotary button control design, portable and convenient.
  • Self-defination of multi-event marks,
  • Directly viewing 1:1 scale of display and print-out waveform.
  • 7-wafer impulse ultrasound transducer, configured with special HR .If correlation reading algorithm to ensure correct and reliable fetal heart rate (FHR) measurement
  • Highly sensitive, wide scope pressure transducer ensures to achieve effective measurement of uterine contraction pressure (TOCO).
  • Fetal movement auto detection.
  • Signal intensity indication ensures effective transducer position.
  • Auto power failure protection and reliable rechargeable Li-ion battery can realize continual monitoring function.
  • Net-working capacity, convenient and ease-of -use. Convenient for hospital informatization management and for data analysis of fetal central monitor system.
  • Meets the standard IEC60601-1,1988, class I ,type B with special protection from electroshock, safe and reliable in use.


Fetal Heart Rate (FHR) MEASUREMENT
Measuring method Ultrasound Doppler
Measuring scope 50-240BPM
Measuring tolerance Less than ±1BPM
Fatal heart rate curve scope 50-240BPM
Fetal heart rate numeric display scope 50-240BPM
Ultrasound working frequency 2MHz 2.5MHz
Ultrasound output Intensity < 5mW/cm2


Uterine Contraction Pressure (TOCO) Measurement
Measuring method External measuring
Measuring scope 0-100 unit
TOCO curve scope 0-100 unit
TOCO numeric display scope 0-100 unit
Non-linearity tolerance Less than ±10%
Auto-zero function Yes
Fetal movement record Manual control button label
Auto fetal movement identification
Display 10.2"oolor TFT-LCD(80RGB*480)
Event mark 9 available
Record mode Thermal array printer
Record paper 112mm x 100mm folded thermal printing paper
Paper feeding speed 1,2,3m/min 3 options
FHR audible and visual alarm Low lime 120BPM, up limit 160BPM
Alarm trigger time < 3s
Printer failure alarm Paper empty alarm
Output volume 2-3W speaker ,volume adjustable
Power Supply AC: 100-240V. 50/6050±1 Hz 40VA
DC: 14.4V/2000rnAh, rechargeable Li-ion battery
Safety level Class I, type B
Size (L)1296 mm x (W)312mm x (H)92 mm
Net-working Capacity Yes